Specifications:

  • 1. Working voltage: 80 ~ 260VAC
  • 2. Test voltage: 80 ~ 260VAC
  • 2. Rated power: 1000A / 22000W
  • 3. Working Frequency: 45-65Hz

A. Function

  • 1. voltage, current, power, energy
  • 2. overload alarm function (over power alarm threshold, the backlight and power flicker tips).
  • 3. The power alarm threshold preset function (can set up their own power alarm threshold).
  • 4.The power button clear function.
  • 5. Power-down data storage function.
  • 6. Large-screen LCD screen full display function (display voltage, current, active power, power).
  • 7. backlight.

B. display and key

I. Display Interface

  •     Display voltage, current, power, energy parameters from the large-screen LCD screen simultaneously.

II. Display Format

1. Power: measurement range 0 ~ 22kW

             1kW display format within 0.0 ~ 999.9W;

              From 1kW display format 1000 ~ 9999W.

              From 10kW display format 10 ~ 22KW.

2. Power: measurement range 0 ~ 9999kWh

              10kWh within the display format 0 ~ 9999Wh;

              Above 10kWh display format 10 ~ 9999kWh;

3. Voltage: Test Range 80 ~ 260V

                 Display Format 80 ~ 220V

4. Current: Test Range 0 ~ 100A

                Display Format 0.00 to 99.99.

III. Button

1. The backlight control

  • By short press the button to turn on or off the backlight, the backlight status automatic storage.

2. The power cleared

  •  Step 1: Press the power button 5 seconds until the digital display window flashes, then release the button;
  • Step 2: If you press the button again, the consumption data is cleared and cleared quit flashing;
  • Step 3: If you press the button again 5 seconds long until no flashing, the charge data is not cleared and exit cleared.

3. The power to set the alarm value

  • Step 1: Press the button, when the LCD screen display “SET CLr” after the release button,

set the value into the power status report.

  • Step 2: Power area displays the current value of the power alarm and the lowest digit starts blinking,

then you can press the button of the digital +1, when there is no key operation more than three seconds,

automatically switches by short digital set as above;

  • Step 3: After setting, press the button more than five seconds to automatically save and exit,

the scope of active power threshold set for the 0.0 ~ 22kW.

Notes:

  • 1. This module is suitable for indoor, not outdoor
  • 2. applied load can not exceed the rated power.
  • 3. The wiring order can not be wrong.

Package include:

  • 1 x Ac Voltmeter / Ammeter
  • 1 x Current Transformer